VOPTIX©, a computer program for graphical display of corneal thickness data

Main Article Content

James V. Schoster, DVM
Cherif Ahrikencheikh, PhD

Abstract

A unique computer program was developed to store and display corneal thickness data taken from a variable array of corneal positions. The program was designed to graphically display the relative corneal thickness profile along any meridian from limbus to limbus as well as a collective representation of the data in a three-dimensional wire grid format. In this paper, the computer program, its graphical output and utilities are described and discussed.

Downloads

Download data is not yet available.

Article Details

How to Cite
1.
Schoster JV, Ahrikencheikh C. VOPTIX©, a computer program for graphical display of corneal thickness data. Digit J Ophthalmol. 1997;3(4). Accessed May 15, 2026. https://djo.harvard.edu/index.php/djo/article/view/949
Section
Original Articles

References

Samuelson DA. Ophthalmic Embryology and Anatomy. In: Veterinary Ophthalmology. 2nd Ed. K. N. Gelatt. Philadelphia: Lea and Febiger; 1991:28-9.

Klyce SD, Beurman RW. Structure and function of the cornea. In Kaufman HE, Barron BA, McDonald MB, Waltman SR, eds. The Cornea. New York: Churchill Livingstone; 1988:4.

Carrington SD, Woodward EG. The Topography of the Anterior Surface of the Cat’s Cornea. Current Eye Research 1984; 31: 823-826.

Carrington SD, Woodward EG. Corneal thickness and diameter in the domestic cat. Ophthal Physiol Opt 1986;6:385-9.

Chan T, Payor S, Holden BA. Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest Ophthalmol Vis Sci 1983;24:1408-10.

Morgan RL, Sorenson SS, Castles TR. Prediction of ocular irritation by corneal pachymetry. Food Chem Toxicol 1987;25:609-13.

Ling T. Osmotically induced central and peripheral corneal swelling in the cat. Am J Optom Physiol Opt 1987;64:674-7.

Martola E, Baum JL. Central and peripheral corneal thickness. Arch. Ophthal 1968;79:28-30.

Remon L, et al. Central and peripheral corneal thickness in full-term newborns by ultrasonic pachymetry. Invest Ophthalmol Vis Sci 1992;33:3080-83.

Chan T, Payor S, Holden BA. Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest Ophthalmol Vis Sci 1983;24:1408-10.

Salz JJ, Azen SP, Berstein J, et al. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters. Ophthalmic Surg 1983;14:750-4.

Poincaire. Patient workup. In Bores LD, ed: Refractive Eye Surgery. Boston: Blackwell Scientific Publications; 1993;120-5.

Siu A, Herse P. The effect of age on human corneal thickness. statistical implications of power analysis. Acta Ophthalmol (Copenh) 1993;71:51-6.

Stucchi CA, et al. Systematic error in computerized pachymetry. Ophthalmologica 1993;207:208-14.

Schoster JV, Wickman L, Stuhr C. The use of ultrasonic pachymetry and computer enhancement to illustrate the collective corneal thickness profiles of 25 cats. Vet Compar Ophthalmol 1995;5:68-73.