VOPTIX©, a computer program for graphical display of corneal thickness data
Main Article Content
Abstract
A unique computer program was developed to store and display corneal thickness data taken from a variable array of corneal positions. The program was designed to graphically display the relative corneal thickness profile along any meridian from limbus to limbus as well as a collective representation of the data in a three-dimensional wire grid format. In this paper, the computer program, its graphical output and utilities are described and discussed.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
References
Samuelson DA. Ophthalmic Embryology and Anatomy. In: Veterinary Ophthalmology. 2nd Ed. K. N. Gelatt. Philadelphia: Lea and Febiger; 1991:28-9.
Klyce SD, Beurman RW. Structure and function of the cornea. In Kaufman HE, Barron BA, McDonald MB, Waltman SR, eds. The Cornea. New York: Churchill Livingstone; 1988:4.
Carrington SD, Woodward EG. The Topography of the Anterior Surface of the Cat’s Cornea. Current Eye Research 1984; 31: 823-826.
Carrington SD, Woodward EG. Corneal thickness and diameter in the domestic cat. Ophthal Physiol Opt 1986;6:385-9.
Chan T, Payor S, Holden BA. Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest Ophthalmol Vis Sci 1983;24:1408-10.
Morgan RL, Sorenson SS, Castles TR. Prediction of ocular irritation by corneal pachymetry. Food Chem Toxicol 1987;25:609-13.
Ling T. Osmotically induced central and peripheral corneal swelling in the cat. Am J Optom Physiol Opt 1987;64:674-7.
Martola E, Baum JL. Central and peripheral corneal thickness. Arch. Ophthal 1968;79:28-30.
Remon L, et al. Central and peripheral corneal thickness in full-term newborns by ultrasonic pachymetry. Invest Ophthalmol Vis Sci 1992;33:3080-83.
Chan T, Payor S, Holden BA. Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest Ophthalmol Vis Sci 1983;24:1408-10.
Salz JJ, Azen SP, Berstein J, et al. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters. Ophthalmic Surg 1983;14:750-4.
Poincaire. Patient workup. In Bores LD, ed: Refractive Eye Surgery. Boston: Blackwell Scientific Publications; 1993;120-5.
Siu A, Herse P. The effect of age on human corneal thickness. statistical implications of power analysis. Acta Ophthalmol (Copenh) 1993;71:51-6.
Stucchi CA, et al. Systematic error in computerized pachymetry. Ophthalmologica 1993;207:208-14.
Schoster JV, Wickman L, Stuhr C. The use of ultrasonic pachymetry and computer enhancement to illustrate the collective corneal thickness profiles of 25 cats. Vet Compar Ophthalmol 1995;5:68-73.